Lift Protocol Test (AGV Ride In/Out)
Walks through the ACS→EL Server flow from the protocol spec §2.2. Each button logs the exact wire message it would send, whether or not a server is connected.
Disconnected
Lift Status
| DId | Status | Floor | Dir | Door | ErrCode | Car_f | Car_r | HallUp_f | HallUp_r | HallDn_f | HallDn_r |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 1 | Idle (0) | Open (2) | 0 | 0 |
0 |
0 |
0 |
0 |
0 |
Phase: 1 / 8
poll current status
Param=9 Data=1 Dest=0 (fixed)
reads status first: hall call if AGV mode is off (Status 9), car call if it is on
repeatable, until arrival at source floor
repeatable, ~1s pulse; Data/Dest fixed 0
destination floor call; Data and Dest both the destination floor
close after entering; Data/Dest fixed 0
repeatable, resend if a passenger cancelled it; Data and Dest both the destination floor
repeatable, until arrival at destination
repeatable, ~1s pulse; Data/Dest fixed 0
close after exiting; Data/Dest fixed 0
Param=9 Data=0 Dest=0 (fixed) - must always run last